Run IPPower under SNMP environment

SNMP IPPower OID list

NameOIDAccessDescrSyntax
ippowerOutlet1.1.3.1read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet2.1.3.2read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet3.1.3.3read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet4.1.3.4read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet5.1.3.5read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet6.1.3.6read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet7.1.3.7read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet8.1.3.8read-writeThis variable controls the current state of the ippower outlet. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerCycleOutlet1.1.4.1read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerCycleOutlet2.1.4.2read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerCycleOutlet3.1.4.3read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerCycleOutlet4.1.4.4read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerCycleOutlet5.1.4.5read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerCycleOutlet6.1.4.6read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerCycleOutlet7.1.4.7read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerCycleOutlet8.1.4.8read-writeThis variable cycles the current state of the outlet. To place power cycle command, set it to 0 or 1. As power on , outlet will turn “ OFF to ON “ when place power cycle command. As power off , outlet will turn “ ON to OFF to ON “ when place power cycle command.INTEGER (0..1)
ippowerOutlet1InitialState.1.5.1read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet1Initia2State.1.5.2read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet1Initia3State.1.5.3read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet1Initia4State.1.5.4read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet1Initia5State.1.5.5read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet1Initia6State.1.5.6read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet1Initia7State.1.5.7read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
ippowerOutlet1Initia8State.1.5.8read-writeThis variable controls the initial state of the ippower outlet after system bootup. To turn on the switch, set it to on (1). To shut off the power , set it to off (0). INTEGER {off (0), on (1)}
outlet1i.1.7.1read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outlet2i.1.7.2read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outlet3i.1.7.3read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outlet4i.1.7.4read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outlet5i.1.7.5read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outlet6i.1.7.6read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outlet7i.1.7.7read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outlet8i.1.7.8read-onlyThe electric current of the ippower outlet.DISPLAYSTRING (SIZE(0..31))
outletTemperature.1.8.1read-onlyThe temperature of the ippower outletDISPLAYSTRING (SIZE(0..31))
outletVoltage.1.8.2read-onlyThe voltage of the ippower outlet.DISPLAYSTRING (SIZE(0..31))