IP POWER9860 8xOutlet | Aviosys a.s.
  • 8x C13/NEMA5 outlet,10A
  • 100~240VAC wire in or IEC309 max 32A
  • 1U-rack size,LCD display
  • 8x Ammeter Voltmeter
  • 2x Ethernet RJ45
  • 1xDI termianl block out
  • 1xUSB for 4G/NBIoT dongle
  • 12VDC power Jack out
  • 1x5VDC out for USB type
  • TV10 surge suppressor
  • Timer inside
  • Option wireless
  • VPN Client




    – 9860MT

    IP9860MT provides remote manual control of the critical devices by clicking on a few buttons on the smart phone or computer webpage. Stop the problem device by cutting off the power to a specific outlet. By cycling the power off and restarting the device remotely, you save time and money by eliminating the need to send technicians to the root cause of the problem. Managers can monitor the total power usage information of PDU from the remote end through the Internet to fully understand the power consumption of all the devices. Set up overload event alerts and notify managers via Email and TRAP, allowing managers to respond to crises in the shortest possible time to minimize disasters. Provide central management software, which can manage a large number of PDUs' power, temperature and humidity information. The database stores the power consumption information of the power strip and provides the history curve chart for the manager's reference.

    – Features

    • LCD information: display ip address, voltage, current and temperature.
    • Support HTTP, HTTPS/SSL, TCP/IP, PPPOE, DHCP, DDNS, SNMP v3, SMTP, NTP, TLS.
    • Support Cloud Connect : AWS IOT, GOOGLE Cloud IoT, Microsoft AZURE IOT.
    • Support Telnet/SSH.
    Equipped with two Ethernet ports, IPPower9820MT can be accessed on two separate networks or VLANs. Auto failover to a 2nd Ethernet-connection in the event of network interruption,ensuring 100% iPDU uptime reporting.
    Command your IPPower through a friendly web interface, via a curl, from a command line, or from your own application via an HTTP get post API(CGI).
    PING Ping function provides 2 IP with with AND OR logic combination. When the specified IP does not respond to PING, IPPower will perform a user-defined power action. The action can be select outlet on/off/power-cycle, shutdown on LAN/wake on LAN and email notification.
    Schedule Task Scheduler allows you to schedule and run actions at pre-defined time table. There are 30 time table which are selected from web calendar of everyday,week or once. When the time up IPPower perform a user-defined power action. The action can be select outlet on/off/power-cycle,shutdown on LAN/wake on LAN and email notification.
    Ammeter Measure each power consumption to balancing circuits, preventing overloads and checking power failures.
    Voltmeter Measure power voltage preventing overloads and checking power failures.
    rfc v1,v2,v3 available
    user can get MIB information from weppage Under SNMP protocol enviroment,user can control power on/off
    and power cycle, chaneg IP/Port
    User-definable power status on/off/last time
    In M2M mode, if you control IPPower-A,
    the other IPPower-B will do the same job.
    It is easy to monitor the remote sites
    Remote Control
    If enable CNT function, please download
    Andriod and ios APP and Nod-red software package
    to control and monitor
    VPN client mode
    IPPower can connect with a VPN router.
    It can be controlled and monitored at the same VPN
    Remote Control
    If enable SMTP function, If the status changed,IPPower will send notifications by email
    If enable POP3 function, IPPower can be controlled from email

    – Specification

    Dimensions 450 x 240 x 45mm( L / W / H )
    Power input 100~240VAC wiring or IEC309 max32A
    Maximum current per outlet 10A
    Maximum current total 8 outlets 32A
    Interface 8 LED indicator lights
    Reset Breaker - Fuse protection button
    DI sensor
    IR Sensor
    HW Reset
    DC 12V Output
    LCD
    Operating temperature 0~50°C
    Network RJ-45 10/100Mb Ethernet port x 2
    Host Port
    Lan Port
    USB USB 2.0 Port

    – Download